CLASS {{p}}t15_hidden DEFINITION PUBLIC FINAL CREATE PUBLIC FOR TESTING DURATION SHORT RISK LEVEL HARMLESS. PRIVATE SECTION. TYPES tt_plant TYPE RANGE OF {{p}}movmt-plant. METHODS run IMPORTING iv_from TYPE d iv_to TYPE d it_plant TYPE tt_plant OPTIONAL RETURNING VALUE(rr_data) TYPE REF TO data. METHODS value_of IMPORTING ir_data TYPE REF TO data iv_row TYPE i iv_col TYPE string RETURNING VALUE(rv_value) TYPE string. METHODS lines_of IMPORTING ir_data TYPE REF TO data RETURNING VALUE(rv_lines) TYPE i. METHODS all_materials_in_range FOR TESTING. METHODS receipt_and_issue_split FOR TESTING. METHODS sorted_by_balance FOR TESTING. METHODS plant_filter FOR TESTING. METHODS date_range_filter FOR TESTING. METHODS ignored_move_types FOR TESTING. ENDCLASS. CLASS {{p}}t15_hidden IMPLEMENTATION. METHOD run. cl_salv_bs_runtime_info=>set( display = abap_false metadata = abap_false data = abap_true ). SUBMIT {{p}}stock_bal WITH p_from = iv_from WITH p_to = iv_to WITH s_plant IN it_plant AND RETURN. TRY. cl_salv_bs_runtime_info=>get_data_ref( IMPORTING r_data = rr_data ). CATCH cx_salv_bs_sc_runtime_info. ENDTRY. cl_salv_bs_runtime_info=>clear_all( ). ENDMETHOD. METHOD lines_of. FIELD-SYMBOLS TYPE STANDARD TABLE. IF ir_data IS BOUND. ASSIGN ir_data->* TO . rv_lines = lines( ). ENDIF. ENDMETHOD. METHOD value_of. FIELD-SYMBOLS TYPE STANDARD TABLE. ASSIGN ir_data->* TO . ASSIGN [ iv_row ] TO FIELD-SYMBOL(). ASSIGN COMPONENT iv_col OF STRUCTURE TO FIELD-SYMBOL(). cl_abap_unit_assert=>assert_subrc( exp = 0 msg = |Column { iv_col } missing| ). rv_value = condense( CONV string( ) ). " The ALV data can show a negative number with a trailing sign. DATA(lv_length) = strlen( rv_value ). IF lv_length > 1 AND substring( val = rv_value off = lv_length - 1 len = 1 ) = '-'. rv_value = '-' && substring( val = rv_value off = 0 len = lv_length - 1 ). ENDIF. ENDMETHOD. METHOD all_materials_in_range. DATA(lr_data) = run( iv_from = '20260101' iv_to = '20260131' ). cl_abap_unit_assert=>assert_equals( exp = 2 act = lines_of( lr_data ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-001` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `MATERIAL` ) ). cl_abap_unit_assert=>assert_equals( exp = `120` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `BALANCE` ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-002` act = value_of( ir_data = lr_data iv_row = 2 iv_col = `MATERIAL` ) ). cl_abap_unit_assert=>assert_equals( exp = `-20` act = value_of( ir_data = lr_data iv_row = 2 iv_col = `BALANCE` ) ). ENDMETHOD. METHOD receipt_and_issue_split. DATA(lr_data) = run( iv_from = '20260101' iv_to = '20260131' ). cl_abap_unit_assert=>assert_equals( exp = `150` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `RECEIPT_QTY` ) ). cl_abap_unit_assert=>assert_equals( exp = `30` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `ISSUE_QTY` ) ). cl_abap_unit_assert=>assert_equals( exp = `40` act = value_of( ir_data = lr_data iv_row = 2 iv_col = `RECEIPT_QTY` ) ). cl_abap_unit_assert=>assert_equals( exp = `60` act = value_of( ir_data = lr_data iv_row = 2 iv_col = `ISSUE_QTY` ) ). ENDMETHOD. METHOD sorted_by_balance. DATA(lr_data) = run( iv_from = '20251201' iv_to = '20260131' ). cl_abap_unit_assert=>assert_equals( exp = 3 act = lines_of( lr_data ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-001` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `MATERIAL` ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-004` act = value_of( ir_data = lr_data iv_row = 2 iv_col = `MATERIAL` ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-002` act = value_of( ir_data = lr_data iv_row = 3 iv_col = `MATERIAL` ) ). ENDMETHOD. METHOD plant_filter. DATA(lr_data) = run( iv_from = '20260101' iv_to = '20260131' it_plant = VALUE #( ( sign = 'I' option = 'EQ' low = '1000' ) ) ). cl_abap_unit_assert=>assert_equals( exp = 2 act = lines_of( lr_data ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-001` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `MATERIAL` ) ). cl_abap_unit_assert=>assert_equals( exp = `70` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `BALANCE` ) ). ENDMETHOD. METHOD date_range_filter. DATA(lr_data) = run( iv_from = '20260101' iv_to = '20260109' ). cl_abap_unit_assert=>assert_equals( exp = 2 act = lines_of( lr_data ) ). cl_abap_unit_assert=>assert_equals( exp = `100` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `BALANCE` ) ). cl_abap_unit_assert=>assert_equals( exp = `40` act = value_of( ir_data = lr_data iv_row = 2 iv_col = `BALANCE` ) ). ENDMETHOD. METHOD ignored_move_types. DATA(lr_data) = run( iv_from = '20260101' iv_to = '20260131' it_plant = VALUE #( ( sign = 'I' option = 'EQ' low = '2000' ) ) ). cl_abap_unit_assert=>assert_equals( exp = 1 act = lines_of( lr_data ) ). cl_abap_unit_assert=>assert_equals( exp = `MAT-001` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `MATERIAL` ) ). cl_abap_unit_assert=>assert_equals( exp = `50` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `RECEIPT_QTY` ) ). cl_abap_unit_assert=>assert_equals( exp = `0` act = value_of( ir_data = lr_data iv_row = 1 iv_col = `ISSUE_QTY` ) ). ENDMETHOD. ENDCLASS.