Files
2026-10-05 18:02:52 +02:00

1.7 KiB

1. Goal

Show the air quality of each measuring station. A dashboard and an OData service will read the values, so the calculation must be in the database, in a CDS view.

2. Open questions

None.

3. Context

  • Table {{P}}STATION (measuring station), package $TMP. Key: STATION_ID (CHAR 10). Fields: STATION_NAME (CHAR 20), LIMIT_PM (DEC 5,1, the permitted fine dust value of the station).
  • Table {{P}}READING (single fine dust reading), package $TMP. Key: STATION_ID (CHAR 10), READING_NO (INT4). Fields: PM_VALUE (DEC 5,1, the measured fine dust value).

4. Contract

  • Create the CDS view entity {{P}}I_AIR_QUALITY in package $TMP.
  • Elements, with these names: STATION_ID (key), STATION_NAME, READING_COUNT, AVG_PM, MAX_PM, RATING, DEVIATION.
  • No authorization check (#NOT_REQUIRED).

5. Business rules

  1. Show one row for each station that has at least one reading. Do not show a station without readings.
  2. STATION_NAME is the name of the station.
  3. READING_COUNT is the number of readings of the station.
  4. AVG_PM is the average PM_VALUE of the readings of the station, with 1 decimal place.
  5. MAX_PM is the highest PM_VALUE of the station.
  6. RATING is the class of the station:
    • 'HIGH' if MAX_PM is greater than LIMIT_PM,
    • 'MEDIUM' if MAX_PM is greater than 80 percent of LIMIT_PM,
    • 'LOW' in all other cases.
  7. DEVIATION is the distance between MAX_PM and LIMIT_PM, as a positive number.

6. Constraints

  • Release target: 8.16.
  • Coding standards: Clean ABAP. No ATC priority 1 or priority 2 findings.
  • Out of scope: do not change {{P}}STATION and {{P}}READING.

7. Acceptance

  • The view is active and has no syntax error.
  • The hidden tests pass.
  • Write ABAP Unit tests with CL_CDS_TEST_ENVIRONMENT in a global test class.